Bourns2056-09-B2LFGasentladungslampen
Gas Discharge Tubes 90VDC 5kADC 2pF Radial Thru-Hole
Compliant | |
EAR99 | |
Active | |
8536.30.80.00 | |
Automotive | No |
PPAP | No |
Protect your expensive outdoor system from lightning surges with this 2056-09-B2LF gas discharge tube from Bourns. Its DC sparkover voltage is 90 V with a tolerance of ±20%, and its impulse discharge current (8x20 us, 10 Hits) is 1 A. This item should be stored between -40 °C and 115 °C. This GDT has a minimum operating temperature of -30 °C and a maximum of 85 °C. It has 3 terminals/electrodes. The 2056-09-B2LF GDT has a radial termination style. This part has a lead diameter of 0.8 mm and a pitch of 4.4 mm. This product is 11.5 mm long.